会议专题

Performance Improvement of Cold Heat Exchanger for High Power Single-stage Pulse Tube Cooler

The cold end heat exchanger in a cryoeooler is of great importance for efficient heat transfer between the working fluid and the heat load,especially for a high power pulse tube cooler (PTC).Calculation results show that the cooling power of single-stage PTC increases significantly by improving the cold end heat exchanger.The total heat conductance of previous cold end heat exchanger(including slot heat exchanger and cold end flow channel)is only 56. lW/K and the heat conductance increases to 112.6W/K after improvement. Experimental results showed that the cooling power of the single-stage PTC increased remarkably with the modified cold end heat exchanger.

Dong W Q Qiu L M Gan Z H Sun H He Y L

Institute of Refrigeration and Cryogenic,Zhejiang University,Hangzhou 310027,P.R.China

国际会议

ICCR 2008 第四届国际低温与制冷工程大会

上海

英文

196-199

2008-04-05(万方平台首次上网日期,不代表论文的发表时间)