Numerical Investigation of the Entire Boiler System with SCR De-NOx Reactor
The numerical investigation of a 300 MW boiler with SCR de-NOX equipment is carried out with advanced methods.The simulation includes furnace, economizer, super-heater, re-heater, air pre-heater, SCR De-NOx equipment, ESP, induced draft fan. A reasonable agreement has been attained when compared with the designed statistics, which proves the reliability of this simulation and implicates its utility value. As a result, an analysis tool is available to study the temperature and pressure characters of the whole boiler system, in a feasible and economic manner.
Boiler system SCR De-Nox reactor numerical simulation
CHENG Xingxing JIN Baosheng
Southeast University,210096,PR China
国际会议
11th International Conference on Electrostatic Precipitation(第11届国际电除尘学术会议)
杭州
英文
567-571
2008-10-15(万方平台首次上网日期,不代表论文的发表时间)