Research on Performance of Electrostatic-Bag Precipitator with Comparative Industrial Tests

The industrial tests made a comparison of three key factors under different filtration velocities, which comprised the outlet emission concentration of dust, grade collection efficiency of PM10 and the rising rate of pressure drop.Meanwhile, the paper provided the reasonable scope of filtration velocity of EBP through the tests, which was helpful for the design and application of large-scale EBP.

EBP PM10 Grade collection efficiency Pressure drop

DANG Xiaoqing SHI Yong MA Guangda LI Dongyang

School of Environmental and Municipal Engineering Xian University of Architecture and Technology,Xian 710055,PR China

国际会议

11th International Conference on Electrostatic Precipitation(第11届国际电除尘学术会议)

杭州

英文

468-471