会议专题

Numerical Simulation of Influence of Baffler in Electric Field Entrance to Form Skewed Gas Flow

This article proposed that baffle plates should be added on the air current distribution boards in inlet box in order to form skewed gas flow. Air distribution was simulated and studied by Software FLUENT. The k-ε2 equation model was taken in the Flow field simulation, and the computation was based on SIMPLE algorithm. There are five sorts of baffle plates which have different fixing angles and fixing spaces to simulate skewed gas flow. Eventually the simulative results indicated that setting baffle plates could form the skewed gas flow and the simulation accorded with the experimental data at 45 degree, space 504 mm.Comprehensively analysed, the angle of 55° was more ideal. All of these offer a basis to design, running and improving of electrostatic precipitator (ESP).

ESP Skewed gas flow Numerical simulation

HU Manyin SUN Xijuan MA Chunhong LIU Yujing WANG Li-qian

School of Environmental Science and Engineering,North China Electric Power University,Baoding 071003 The Chinese Society of Electrostatic Precipitation,Nanjing 210008,PR China

国际会议

11th International Conference on Electrostatic Precipitation(第11届国际电除尘学术会议)

杭州

英文

187-193

2008-10-15(万方平台首次上网日期,不代表论文的发表时间)