Safety Test Research of Gluing the Steel Plates to Block up Grade-6 Civil Air Defense Access

This article through glues the steel plates to realize a typical garage civil air defense access block up design proposal, and by the three dimensional finite element power numerical analysis with the fmite element analysis software to realize it, and by the similar design after the original design plan, By the structure of gluing the steel plate explode test in the mold of the noclear explosion pressure simulator, obtained along the vertical support steel plate displacement and the strain time interval curve, and by the contrast with the fmite element numerical solution, its result tallied very well, confirmed structure gluing the steel plate under grade-6 of civil air defense explosive shock wave could safety handled, explained gluing the steel plate design model under grade-6 of civil air defense explosive shock wave was feasible. From this proved it is security to use this kind of technology and the superiority which the peacetime and wartime function transforms. Not only the research results have the academic value, moreover it has the application prospect.

The civil air defense access sticks the steel explode load shock-wave security

WU Zhiping YANG Linde

Department of Civil Engineering,Shanghai Institute of Technology,Shanghai 200233,China Department of Geotechnical Engineering,Tongji University,Shanghai 200092,China