Physical Analysis of Volatilization Combustion during Coalfield Fire
The physical models on the volatilization combustion were established in the light of its characteristics of coalfield fire area. The equations of mass exchange, momentum, diffusion and energy with the thermal and quality exchange and the chemical reaction and multi-composition flow were setup and analyzed by analytic method. The parameters of volatilization combustion speed, the content of the volatile component and the flame temperature were obtained at relatively still high temperature environment. Through results analysis, the flame temperature of the volatilization combustion of coal field fire area is the heat insulation temperature calculating in the light of low-beat value of the volatile component. It is concluded that, in actual coalfield fire area, the true temperature would be lower than that in the calculation because of the natural or forced convection.
coalfield fire area volatile combustion physical analysis pyrolysis spontaneous combustion of coal seam
LU Guodong QU Zhiming JIANG Jie LI Jinxian
School of Resource and Safety Engineering,China University of Mining and Technology,Beijing 100083,C School of Civil Engineering,Hebei University of Engineering,Handan 056038,Hebei,China School of Art and Law,China University of Mining & Technology,Beijing 100083,China Institute of Technology,Yichun University,Yichun 336000,Jiangxi,China
国际会议
The 2008 International Symposium on Safety Science and Technology(2008年安全科学技术国际会议)
北京
英文
1336-1340
2008-09-24(万方平台首次上网日期,不代表论文的发表时间)