会议专题

Study on the oxygenation capacity and energy efficiency of aeration tank using cellular filler

The first stage test on clean water aerating confirmed that mass transfer efficiency of oxygen transfer in aeration process was significantly enhanced through adding cellular standpipe filler into the gas-water two-phase system;and that the smaller diameter in a certain range of the filter was more effective.The follow-up sewage treatment experiment in sequencing batch operation further demonstrated that the biological treatment efficiency was improved,the processing time was shortened and the smaller diameter in a certain range of filler was more significantly efficient,by adding the cellular standpipe filler packed into aeration tank.The results revealed that packing small-diameter of cellular standpipe filler into aeration tank was practical for increasing oxygenation capacity,thereby for improving mass transfer efficiency as well as for saving energy.

aeration tank oxygenation capacity cellular stand filler energy efficiency mass transfer

Li CHENG Heli WANG Nan JIANG

College of Resource and Safety Engineering,China University of Mining and Technology,Beijing 100083, School of Water resources and Environment,China University of Geosciences,Beijing 100083,China

国际会议

The International Conference on Advances in Chemical Technologies for Water and Wastewater Treatment(2008年化学技术对水及废水处理国际研讨会)

西安

英文

667-671

2008-05-15(万方平台首次上网日期,不代表论文的发表时间)