A study on Energy Load of S residence unit by comparison with RC unit
Recently, fight against global warming is becoming more and more important. As a main energy consumer, air-Conditioning loads (hereinafter referred to as AC loads) are becoming an important issue in our life.Therefore, effect of heat insulation styles and AC patterns on AC load should be verified before the building is constructed.This paper examines AC loads of two different kinds of residence units which are S (Steel) unit and RC (Reinforced concrete) unit. For this examination, the dynamic simulation software THERB(the simulation software of the thermal environment of residential buildings) is employed.Three AC patterns are investigated. The setting temperature for heating is assumed to be 17℃, and the setting temperature for cooling AC to be 28℃.Two cases of RC residence unit (inside and outside) and one case of S residence unit (inside) exterior wall insulation have been examined.By the comparison with inside and outside insulation of exterior wall of RC unit,insulation case has prominent effect on AC load. In the case of exterior wall inside insulation of RC unit, the AC load is lower than exterior wall outside insulation of RC unit and somewhat close to the AC load of S unit.
AC Load Temperature Heat Capacity AC Pattern Heat Insulation
Yupeng Wang Yuko Kuma Hiroatsu Fukuda Ozaki Aklhito
Graduate School,The University of Kitakyushu of Japan Prof.,The University of Kitakyushu of Japan,Dr.Eng Prof.,Kyoto Prefectural University of Japan,Dr.Eng
国际会议
北京
英文
260-263
2008-10-01(万方平台首次上网日期,不代表论文的发表时间)