SELF BREAKDOWN PROPERTIES AND OPTIMUM OF INSULATOR ENVELOPE FOR MV GAS SWITCHES
Two insulator bracing type MV gas switches are developed. One switchs HV electrode is cantilever and the insulator envelope is integrated. The others HV electrode is out of insulator envelope and the brace cylinder is sectioned. Through self breakdown experiments and electrostatic field simulations, the optimum design of insulator envelopes is discussed and the reason for puncturing on the envelope of cantilever switch is given. The self breakdown properties of switches are discussed as well.
MV gas switch insulator envelop insulation damage breakdown electric-field intensity
YIN Jia-hui SUN Feng-ju QIU Ai-ci GUO Jian-ming ZHANG Zhong LIU Zhi-gang ZENG Jiang-tao
Northwest Institute of Nuclear Technology,P.O.Box 69-10,Xian,710024,China
国际会议
17th International Conference on High-Power Particle Beams(第17届高功率离子束国际会议)
西安
英文
595-598
2008-07-06(万方平台首次上网日期,不代表论文的发表时间)