LASER TRIGGER SYSTEM FOR MULTI-MODULE FACILITY
The laser trigger system for multi-module was built and applied in the single module high power pulse device.The fourth harmonic (λ:266 nm) Q-switched Nd:YAG laser was used to trigger the 5 MV multi-gap multi-channel laser triggering switch. Three lasers were tested together. The experiment results show that maximum deviation (Max-Dev) and standard deviation (StDev) of jitter time of one laser is ±1.5 ns and 0.3 ns. The maximum jitter is lower than ± 2.5 ns between any two lasers.
He An Wan Yujuan Feng Suping Li Hongtao Gu Yuanchao Xie Weiping
Institute of Fluid Physics,CAEP,P.O.Box 919-108,Mianyang 621900,China
国际会议
17th International Conference on High-Power Particle Beams(第17届高功率离子束国际会议)
西安
英文
462-463
2008-07-06(万方平台首次上网日期,不代表论文的发表时间)