会议专题

DIAMAGNETIC LOOP DIAGNOSES EMITTANCE OF INTENSE PULSE BEAM

The technology of diamagnetic loop diagnosing intense pulse beam is on-line diagnostics. The technology can diagnoses beam emittance and obliquity on-line cooperating with other technology such as three gradient method. In this paper, we introduce theory of diamagnetic loop, design and calibrate diamagnetic loop device. And we diagnose Dragon-I accelerator electron beams radius and emittance. By the DML, average beam radius in the flat of pulse in the !2th accelerator cavity is 17.25mm, which are accordant with the result of CR measuring. Emittance at the exit of accelerator is 2480 π·mm·mrad.

diamagnetic loop(DML) emittance MTGM beam radius magnetic moment

Fan Mu Chengjun Liu Liansheng Xia

Institute of Fluid Physics,CAEP,P.O.Box 919-106,Mianyang 621900,China

国际会议

17th International Conference on High-Power Particle Beams(第17届高功率离子束国际会议)

西安

英文

262-263

2008-07-06(万方平台首次上网日期,不代表论文的发表时间)