EXPERIMENTAL RESEARCH ON THE VOLTAGE DISTRIBUTION OF TESLA TRANSFORMERS TAPER WINDINGS
By use the taper high voltage windings, the Tesla transformer with compact structure can be built. However, the flashover between coils will occur because of un-uniform of the voltage distribution along the windings. Therefore, researching the voltage distribution of the Tesla transformer, improving the distribution by appropriate method and designing optimized structure of the windings would highly improve repetitive ability of the transformer, which have theoretical and engineering significance for the Tesla transformers working in reliable and security. In order to study the voltage distribution on the pulse transformers taper windings, according to the structure of the factual pulse transformers taper windings, the voltage of a uniform tesla transformers windings was measured in the paper. It is shown that the voltage distribution of taper winding is not uniform, and the distributed curve of its interturn voltage is U shape with 100ns pulse. Based on the results, the methods to improve the distribution of the tape winding were bring forwards by measuring and analyzing the voltage distribution of other taper windings with different structure. These results can give some references to interturn insulation designs of Tesla transformers windings.
Li Mingjia Kang Qiang Xin Jiaqi
Institute of Applied Electronics,CAEP,Mianyang,China;Graduate School of China Academy of Engineering Institute of Applied Electronics,CAEP,Mianyang,China
国际会议
17th International Conference on High-Power Particle Beams(第17届高功率离子束国际会议)
西安
英文
258-261
2008-07-06(万方平台首次上网日期,不代表论文的发表时间)