INVESTIGATIONS OF COLD CATHODE EMISSION IN GAS AND VACUUM WITH PICOSECOND RESOLUTION

Electron beam formation in magnetically insulated coaxial diode with tubular cold cathode and a strongly non-uniform electric field was investigated with picosecond resolution. Voltage pulses of amplitudes up to -170 kV (in a traveling wave mode) and FWHM not exceed 250 ps were applied to the cathode. Under such accelerating pulse parameters the polishing effect has a fundamental influence on the emissive characteristics. The time and amplitude parameters of electron beam injection were compared experimentally for different cathode materials with gas or vacuum insulation of accelerating gap.

Gennady Mesyats Sergey Shunaylov Konstantin Sharypov Valery Shpak Michael Yalandin

Lebedev Physical Institute of Russian Academy of Sciences,Moscow,119991,Russia Institute of Electrophysics UB RAS,620016,106,Amundsen Street,Ekaterinburg,Russia