STUDY AND AERODYNAMIC DESIGN OF CENTRIFUGAL COOLING FAN ON ELECTRIC MULTIPLE UNITS

A centrifugal cooling fan on multiple units was designed based on one-dimensional calculation and three-dimensional numerical simulation. Limited by space of the locomotive, inlet piping layout and the axial exhaust requirement the design became much more difficult. The three-dimensional model was presented based on one-dimensional calculation. Numerical simulation and thorough analysis were carried out on the blower with software NUMECA. The model machine was manufactured based on the optimal project, and the performance experiment of the centrifugal blower was conducted. The results of the experiment indicated that the inlet and outlet flow field was uniform and steady, the aerodynamic performance, vibration and noise performance were remarkably improved compared with the imported blower, especially the power was decreased by 2kw.

multiple units centrifugal cooling fan numerical simulation

Li Lili Wang Xiaofang Qu Yuekun Feng Junwei

Key Laboratory of Ocean Energy Utilization and Energy Conservation of Ministry of Education, School Shenyang Blower Works Group Co., Ltd, Shenyang, 110142

国际会议

the 3rd World Congress on Engineering Asset Management andIntelligent Maintenance Systems(第三届世界工程资产管理及智能维修学术大会)

北京

英文

923-926