Detection of Protective Coating Disbonds in Pipe Using Circumferential Guided Waves
Disbonded protective coatings greatly increase the corrosion rates in pipeline. A new guidedwave technology is developed for the detection of disbonds. Theoretical dispersion curves are generated for shear horizontal waves propagating around the circumference of a pipe. Three parameters are identified for the detection of disbonded coatings. Disbond detection is demonstrated experimentally using a 20 diameter pipe with a hot-applied coal-tar coating.Results show that there is potential for disbond sizing in addition to detection.
Circumferential guided waves Coating Disbond Pipe SH-waves
Jason K. Van Velsor Joseph L. Rose FBS, Inc. J. Bruce Nestleroth
Pennsylvania State University Department of Engineering Science & Mechanics 212 Earth & Engineering Pennsylvania State University Dept. of Eng. Science & Mechanics 212 Earth & Eng. Science Bldg.Univer 143 Hawbaker Industrial Dr.Suite 102 State College, PA 16803, US Battelle Memorial Institute 505 King Avenue Columbus, OH 43201, US