DEVELOPMENT OF SEISMIC DESIGN CRITERIA FOR RIVER FACILITIES AGAINST LARGE EARTHQUAKES
This paper introduces the fundamental concept of seismic design of river facilities against large-scale earthquakes described in the Performance-based Seismic Design Criteria for River Facilities (Draft) recently compiled by the Ministry of Land, Infrastructure and Transportation (MLIT) on 2007.3. River facilities include levees, self-supporting structural levees, sluiceways, water gates, weirs and drainage pumping station. As background, characteristics of damage induced in river facilities by past earthquakes, and the history of revision of the Technical Criteria for River Works and Sabo Works (Draft) Volume of Design are also briefly reported.
Earthquake Damage Large Earthquake River Facilities Seismic Design Criteria
Hideki SUGITA Keiichi TAMURA
Soil Mechanics and Dynamics Team, Public Works Research Institute, Japan Research Coordinator for Earthquake Disaster Prevention, NILIM, Japan
国际会议
14th World Conference on Earthquake Engineering(第十四届国际地震工程会议)
北京
英文
2008-10-12(万方平台首次上网日期,不代表论文的发表时间)