PERFORMANCE BASED SEISMIC AND WIND ENGINEERING FOR 60 STORY TWIN TOWERS IN MANILA
This paper describes the structural design of two similar 60 storey towers in Manila using performance based procedures for seismic and wind actions. High-rise buildings designed by performance based methods not only perform better than conventionally designed ones, but are also less expensive to construct. The buildings incorporate the Arup Damped Outrigger System, and the savings realized by this are discussed.
High-rise building performance based design viscous dampers wind seismic
M.R. Willford R.J. Smith
Director, Arup, 13 Fitzroy Street, London, W1T 4BQ, UK Associate Director, Arup, 13 Fitzroy Street, London, W1T 4BQ, UK
国际会议
14th World Conference on Earthquake Engineering(第十四届国际地震工程会议)
北京
英文