DYNAMIC BEHAVIOR OF A SEISMIC ISOLATED STRUCTURE IN GREECE
Onassis House of Letters and Arts is a cultural center with hallmark architecture. In order to satisfy the architectural requirements as well as the high performance seismic specifications that were set, a seismic isolation system of FPS type bearings was employed. This study focuses on the methodology followed for the seismic design which, performed in three consecutive steps, includes simple calculations using an equivalent SDOF model, dynamic response spectrum analyses and non-linear time-history analyses using selected earthquake records on a 3-D finite element model. Results indicate good agreement between different analyses and shed light to the behavior of a complex, seismic isolated structure under seismic loads.
Seismic Isolation Friction Pendulum System Nonlinear Time-History Analysis
C. Giarlelis C. Kostikas E. Lamprinou M. Dalakiouridou
Civil Engineers, OMETE SA Consulting Engineers
国际会议
14th World Conference on Earthquake Engineering(第十四届国际地震工程会议)
北京
英文
2008-10-12(万方平台首次上网日期,不代表论文的发表时间)