Thermodynamic Properties of a New Heat Pump Working Pairs Containing Ionic Liquid :Ⅱ.The Measurement and Correlation of Excess Enthalpies of Binary System Containing Ionic Liquid

Ionic liquids 1-Ethyl-3-methylimidazoliumEthyl sulfate (EMISE) +H2O mixture exhibit properties which render them suitable as candidates for working pairs in absorption heat pumps or chills. The excess enthalpies (H E ) of binary system for EMISE with water were measured at different temperature (T=303.15k, 313.15k, 323.15k) under the pressure of 0.1MPa over the range of mole composition of EMISE from 0.1 to 0.7 by an adiabatic mixing-heating apparatus. The results show that the mixing heat of the system investigated was negative. The experimental excess enthalpies (H E ) data were correlated using NRTL model in which linear temperature dependent interaction parameters were used. The results validated that the NRTL model can be used to describe the excess enthalpies well.

Ionic liquids Excess Enthalpy working fluids NRTL Correlation

Shuanghua Yan Zongchang Zhao Guilan Zuo

Research Institute of Chemical Engineering, Dalian University of Technology, 158 Zhong Shan Road, Dalian, PC116012, China

国际会议

The 12th Asian Pacific Confederation of Chemical Engineering Congress(第十二届亚太化工联盟大会暨化工展览会)

大连

英文

2008-08-04(万方平台首次上网日期,不代表论文的发表时间)