Numerical Analysis of Resistive Torques during the Start up of a Reciprocating Compressor

Most simulation methodologies for compressors available in the literature consider a steady state operating condition.However,several phenomena that affect the compressor energy efficiency,noise level and reliability are associated with transient effects that occur when the compressor is either switched on or switched off.This paper presents a numerical analysis of the compressor start up,with special attention to the resistive torques that take place in the first compression cycles.The results show that the equalization pressure level greatly affects the torque that the electrical motor must overcome during the compressor start up.

Reciprocating compressor Compressor start up Resistive torque

Rodrigo Link Cesar J.Deschamps

EMBRACO,Joinville,SC,Brazil POLO-Research Laboratories for Emerging Technologies in Cooling and Thermophysics Federal University

国际会议

第六届压缩机与制冷国际会议(The 6th International Conference on Compressor and Refrigeration(ICCR))

西安

英文

151-159

2008-09-25(万方平台首次上网日期,不代表论文的发表时间)