The General Topological Template and The General Steam-water Distribution Equation of Thermal System for the Coal-fired Power Unit

The structure of thermal dynamic system for the coal-fired power unit is various and complicated. So, it is comparatively difficult and tedious to set up the steam-water distribution equation. Based on summarizing the characteristics and the steam-water distribution equation of different thermal dynamic systems, the author of this paper puts forward the general topological template of thermal dynamic system with concise structure, which simplifies the course of setting up the steam-water distribution equation. The equation set up on this basis is characteristic of simple structure, being adapted to various thermal dynamic systems, and being easily solved. It provides a new method to the analysis of the thermal energy-economy and consumption difference for the coal-fired power unit with the general topological template and the general steam-water distribution equation.
Thermal system General topological template Steam-water distribution equation
Yan Shunlin Xuhong
Key Laboratory of Condition Monitoring and Control for Power Plant Equipment of Ministry of Educatio Key Laboratory of Condition Monitoring and Control for Power Plant Equipment of Ministry of Educatio
国际会议
2007杭州国际动力工程会议(The International Conference on Power Engineering 2007)
杭州
英文
2007-10-23(万方平台首次上网日期,不代表论文的发表时间)