The Strength Analysis for U Drum Bolt of Large Capacity Boiler
The drum of a boiler is usually supported by two U bolts. For large capacity units. The load acting on each U bolt can reach as high as 400 tons. So it is very important to ensure the safety of the U bolt. The article starts from the beam’s tensile-bending differential equation, and get the bending moment formulae of bolt in some boundary conditions. It also comes up with the unified formulation in different loading conditions, which could be directly used in the U bolt design.
U bolt Tensile-bending differential equation Safety Unified formulation
WU Ru Song Mao Bing Hui
Design department , Shang Hai Boiler works Ltd.
国际会议
2007杭州国际动力工程会议(The International Conference on Power Engineering 2007)
杭州
英文
2007-10-23(万方平台首次上网日期,不代表论文的发表时间)