会议专题

The Ammonia Injection System on the Flue Gas Duct before the Electrostatic Precipitator Inlet in Zhangjiang Orimulsion Power Plant

The characteristics of Orimulsion are described, and the necessity and feasibility of adopting the ammonia injection technology on the flue gas duct before the electrostatic precipitator inlet is presented. The flows of ammonia storage, evaporation and injection system are illustrated. The requirements for the system design are proposed according to the reaction principle and the characteristics of ammonia. The design features of the system are outlined subsequently. The selections of main devices are briefly introduced.

Orimulsion High content of sulfur Electrostatic precipitator Ammonia Ammonia injection system Requirements for design Design features Selection of devices

HU Kun MA Xue-song

Guangdong Electric Power Design Institute, Guangdong Guangzhou, 510600

国际会议

2007杭州国际动力工程会议(The International Conference on Power Engineering 2007)

杭州

英文

2007-10-23(万方平台首次上网日期,不代表论文的发表时间)