ASSESSMENT STRUCTURAL INTEGRITY OF OPERATED HIGH ENERGY EQUIPMENT AND PIPING OF FOSSIL, NUCLEAR, CHEMICAL AND REFINERY PLANTS BY QUANTATITIVE ACOUSTIC EMISSION NON-DESTRUCTIVE INSPCTION METHOD
Increased requirements for the safety and reliability of potentially dangerous equipment and structures stimulated us to create and develop a new AE technology that would also make it possible to reveal, identify and assess the danger level of individual and interacting flaws according to fracture mechanics criteria. We started this work at the beginning of the nineteen eighties and created our technology, entitled The Quantitative Acoustic Emission Non- Destructive Inspection (QAE NDI) technology. In the following we shall describe results of using it to inspect high energy piping in fossil and nuclear power plants, and in chemical industry.
G. Muravin B. Muravin L. Lezvinsky
Margan Physical Diagnostics Ltd., P.O.B. 8155 Netanya 42160, Israel
国际会议
第九届工程结构完整性国际会议(The Ninth International Conference on Engineering Structural Integrity Assessment)
北京
英文
2007-10-15(万方平台首次上网日期,不代表论文的发表时间)