会议专题

THE LOAD CARRYING CAPACITY OF THIN-WALLED STEEL I-GIRDER SUBJECTED TO ECCENTRIC PATCH LAODING

Based on the latest experimental study, the load carrying capacity of the thin–walled steel Igirder subjected to eccentric patch loading has been analyzed in this paper. And a new predicting expression is proposed to determine the load carrying capacity of the thin-walled steel I-girder subjected to eccentric patch loading in this paper. The comparison of the calculating results obtained from the new predicting expression with the test results shows that the new proposed expression is reasonable and conservative.

Guo Peng Guo Chengxi

University of Architecture & Technology, engaged in the study of light-gauge steel structures.

国际会议

第九届工程结构完整性国际会议(The Ninth International Conference on Engineering Structural Integrity Assessment)

北京

英文

2007-10-15(万方平台首次上网日期,不代表论文的发表时间)