会议专题

Non-Destructive Evaluation (NDE) of Double Base Propellant (EDB) Grains Using Computed Tomography (CT) System

Computed Tomography (CT) has been widely used in various medical and non-medical fields. It is also considered an appropriate tool for identification of defect in solid rocket propellants like extruded double base (EDB) propellants. Data in terms of CT number for EDB propellants with different composition; compaction pressure and inhibition materials have been generated for defect identification. Data on CT number reveals that Polyurethene (PU) based inhibition material results in decrease of the CT number range whereas the addition of antimony oxide in the base PU material results in increase in the average CT number as well as the range of CT numbers. The EDB grain having interfacial defect has also been analyzed with the help of CT number for proper identification.

double base propellant computed tomography NDE

Bikash GHOSE S S PUNDALE S N SINGH

High Energy Materials Research Laboratory, Pune-411 021, India

国际会议

2007国际推进剂、炸药、烟火技术秋季研讨会(The 2007 International Autumn Seminar on Propellants,Explosives and Pyrotechnics)

西安

英文

96-101