Measures for the Termination of the History of No Concrete Dam without Cracking

Although a series of measures have been developed to prevent cracking in concrete dams since 1930, practically there is no dam without cracking. After systematic investigation, the author discovered that the basic reason is the neglect of superficial thermal insulation in the later age of concrete. It is possible to prevent cracking in concrete by permanent superficial thermal insulation in addition to comprehensive temperature control in the construction period. There are three concrete dams without cracking after completion in China. The cost of permanent superficial thermal insulation is rather low.

concrete dam crack permanent superficial thermal insulation

Zhu Bofang

China Institute of Water Resources and Hydropower Research, Beijing 100038, China

国际会议

第五届碾压混凝土坝国际研讨会(The Fifth International Symposium on Roller Compacted Concrete(RCC))

贵阳

英文

3-8

2007-11-02(万方平台首次上网日期,不代表论文的发表时间)