会议专题

Structural Health Monitoring for Subway Station Structure

A structure health monitoring (SHM) system set up in a Beijing subway station is presented. Based on the static analysis and Effective Independence (EfI) method, sensors are installed in optional locations in the station strutting. Through the SHM system, a series measurements for temperature and strains of the station structure were carried out during the station construction by using fiber Bragg grating (FBG) sensors and vibrating wire (VW) sensors, the data measured by the two types of sensors agree very well with each other. The change of structure strains at some special eases in the course of construction can be captured by the SHM system. In addition, an application of GIS technology in the SHM system for the subway station structure also introduced.

Structure health monitoring Subway station structure FBG sensor GIS

Yuanfeng Wang Bing Han Yao Zhou Changdong Zhou Huidong Zhang

School of Civil Engineering and Architecture, Beijing Jiaotong University, Beijing 100044, China

国际会议

结构、材料与环境健康监测国际会议(International Conference on Health Monitoring og Structure,Material and Environment)

南京

英文

342-346

2007-10-16(万方平台首次上网日期,不代表论文的发表时间)