Subway Station Structure Monitoring by Fiber Bragg Grating Sensors

Performance test results of Fiber Bragg grating (FBG) sensors show that FBG sensors have high sensitivity and long-term stability. Based on the theory of heat of hydration, the temperature of soleplates is calculated by finite element (FE) method. FBG sensors have been applied successfully in health monitoring of Guomao Station. Compared with results measured by vibrating wire (VW) sensors and computed by finite element method, the monitoring results show temperature and strains can be accurately measured by FBG sensors. The strains of the secondary lining is first monitored in the world. Through the strains of sections, section moments are also obtained.

Structure monitoring FBG sensor Subway station Heat of hydration Secondary lining

Yao Zhou Yuanfeng Wang Bing Han Changdong Zhou

School of Civil Engineering and Architecture, Beijing Jiaotong University, Beijing 100044, China

国际会议

结构、材料与环境健康监测国际会议(International Conference on Health Monitoring og Structure,Material and Environment)

南京

英文

522-526

2007-10-16(万方平台首次上网日期,不代表论文的发表时间)