会议专题

The Reactive Power Compensation Analysis System of Substation Based on Typical Day Load Curve compensation.

The Reactive power compensation is one of the important measures for lowering energy loss. The reactive power compensation of substation can select switching pattern according to different stages and capacities, but the determination of switching time and capacity is lace of necessary theoretical bases. The system can obtain typical day-load curve through the analysis of the change of load during certain stage and can calculate more rational switching time and capacity. This has certain guiding significance to set the reactive power compensation plan.

reactive power compensation typical day-load curve switching of capacitors lowering energy The Reactive Power Compensation Analysis System of loss

周小波 张俊敏 汤晓伟 许敏

上海市电力公司,上海200122 上海市电力公司松江供电分公司,上海201600

国际会议

第六届输配电技术国际会议

广州

英文

2007-11-10(万方平台首次上网日期,不代表论文的发表时间)