会议专题

Mathematical Model of Large Axial-flow Fan and Its Use in on-line Monitoring1

This paper investigates the practical 1 performance of large axial-flow fans used as the boiler forced draft fan and induced draft fan of thermal generating units of 300MW or over in capacity. A common mathematical performance model is set up with computer assistance. Then its application in operating fan`s on-line monitoring and surge prognosis is further studied. It is shown by study that the model is rational and its application is feasible. It is obviously significant for improving the safety and economy of the pirating fans.

on-line monitoring axial-flow fans

WANG Shuli WANG Hai Xiu SHI Xiaojun ZHANG Yuanxiu

Jiangsu Polytechnic University,Jiangsu Key Laboratory of Oil & Gas Storage and Transportation Technology, China

国际会议

第七届国际测试技术研讨会

北京

英文

2007-08-05(万方平台首次上网日期,不代表论文的发表时间)