Error Evaluation of BAQ Algorithm for Calibration Data of Spaceborne SAR
BAQ is the efficient algorithm for SAR echoes data compression that has the Gauss distribution. Internal calibration is the important system resource, which is to calibrate the system gain change before and after the imaging and also provide more accurate reference function for the range compression. But the echoes are different from calibration data. This paper discussed whether the error brought by BAQ compression algorithm could be accepted by this system. Both the theoretical simulation and the experimental results indicate that the internal calibration data only can be directly transmitted but not compressed, which has the important reference to engineering design.
BAQ: Algorithm internal calibration SAR Error
Yan CHEN XiaoBing MA
ElectrIc Power-Supply Bureau, Shizuishan, 753200, China Graduate School of Chinese Academy of Science, Beijing, 100039, China
国际会议
北京
英文
2007-08-05(万方平台首次上网日期,不代表论文的发表时间)