会议专题

Design of Air Injection Pump Using for Methyl Iodide Generator

In order to effectively avoid radioactive gas escaping out from high pollution zone to low pollution zone, reduce weight and volume, the methyl iodide generator used air injection pump. Through performance test of air injection pump, prove that design formula of air injection pump is reasonable. The results of test show that air injection pump have better turn-down ratio, it can hold predefined differential pressure and avoid radioactive gas escaping outside.

methyl iodide iodine adsorber air injection pump vacuum

MEI Ying

North University of China, Taiyuan 030051

国际会议

第七届国际测试技术研讨会

北京

英文

2007-08-05(万方平台首次上网日期,不代表论文的发表时间)