会议专题

Research of micromachined acceleration switch based on contactless configuration

Typical acceleration micro-switches have contained at least one electrical contact.. The contacts are designed to close when the threshold acceleration value is detected. The contacts are formed with a metal, such as gold. However, there may be problems with the use of metal contacts, such as microwelding, arcing, and oxidation. These problems may contribute to the failure of the switch. So this paper introduces the design fundamental, study methods and primary fabricated process of a contactless microswitch, and discusses the coupling the impact force and electrostatic force, the result is proved through ANSYS software.

acceleration micro switches contactless low actuation voltage1

Li Lihua Guo Tao Xiong Jijun Xu Xiaohui

National Key Laboratory for Electronic Measurement Technology,Key Laboratory of Instrumentation Scie Luoyang College of technology, luoyang, Henan 471023, China

国际会议

第七届国际测试技术研讨会

北京

英文

2007-08-05(万方平台首次上网日期,不代表论文的发表时间)