Numerical Simulations of Sinusoidal Test Apparatuss Flow-Field Uniformity Affect to the Metrical Results

In order to study the sinusoidal test apparatuss (STAs) flow-field uniformity affect to the metrical results, this paper use computational fluid dynamics (CFD) numerical simulation method and divisional mesh technique to investigate the inner flow-field of a STA. Control-volume-based technique and Gauss-Seidel method are used to get the result of governing equation, and contours of all flow-field pressure and static pressure are given. The governing equations of flow are unsteady 2-dimensions Reynolds Averaged Navier-Stokes equations. The model of turbulence is Realizable k-epsilon model, and Two-layer zonal model is used near the wall. Use multilayer mesh technique to quicken convergence. Numerical simulation results show that the inner flow-field configurations of STA are very complex, which contain vortex, flow separation, shock etc. It also can be conclude that at the same inlet condition, the flow character of the pressure chamber mainly depends on the exhaust port acreage, and the flow-field uniformity affect the metrical results is not very obviously, These conclusions can be used in the over all design of STA, and it is also useful for the selection of structure and pneumatic parameters of pressure chamber.

Sinusoidal test apparatus (STA) Pressure chamber Computational fluid dynamics (CFD) Navier-Stokes equations Numerical simulations

WANG Yufang LI Cheng YU Jin LI Xin LIU Jing

Changcheng Institute of Metrology & Measurement, P.O. Box 1066, Beijing 100095, China

国际会议

第七届国际测试技术研讨会

北京

英文

2007-08-05(万方平台首次上网日期,不代表论文的发表时间)