会议专题

The Dynamic Model of Doubly-fed Induction Generator Based on Wind Turbine

According to grid codes issued by utilities, tripping of wind turbines following grid faults is not allowed, and it is necessary to provide reactive power support to grid sometime. So this paper sets up a complete DFIG dynamic model, including the generator model, converter model and converter protection, grid model etc. To study the transient characters. The method of sensorless direct torque control (DTC) and model referencing adaptive system (MRAS) method were used in the converter control. At last, the results of simulation on DFIG transient power control performance based on 1.5MW SUT-1500 wind turbine prototype indicated that the DTC control and the MRAC principle improve the system phase-ground fault ride-through capacity ,and fulfil the dynamic regulating of the DFIG external fault .

DFIG Dynamic model DTC

Xingjia Yao Hongxia Sui Zuoxia Xing Dayong Liu

Wind Power Technique Institute Shenyang University of Technology Shenyang City ,Liaoning Province, C Electric Power Department of Changchun Changchun city of Jilin Province

国际会议

2007 IEEE International Conference on Automation and Lofistics

山东济南

英文

2007-08-18(万方平台首次上网日期,不代表论文的发表时间)