Camera Calibration Method in Reverse Engineering
Based on the two-dimensional method, camera calibration method was proposed in reverse engineering. First, obtain the initial value through the linear method; second, considering the radical and tangential distortion, optimize the results using maximum likelihood estimation method through the nonlinear method; at last, minimize the error by modifying the actual image point repeatedly. The experimental errors are 0.30267 pixels and 0.24683 pixels, respectively. This demonstrates that the method has a higher accuracy and is an effective and simple calibration method.
Camera calibration Planar pattern Reverse engineering
Qiujuan Lv Genliang Hou Zimig Luo Qiujuan Lv Genliang Hou
State Key Laboratory for Manufacturing Systems Engineering , Xian Jiaotong University Xian Jiaoton Mechanical Department Xian Research Inst. of Hi-Tech Xian,Shanxi Province, China
国际会议
2007 IEEE International Conference on Automation and Lofistics
山东济南
英文
2007-08-18(万方平台首次上网日期,不代表论文的发表时间)