Study of Temperature and Humidity of Chuan Xi Continuous Cocoon Drying Machine
The temperature and humidity of the air-heated continuous cocoon drying machine were measured with the device of our laboratory. The data were analyzed from two aspects. One was the shortcoming of cocoon drying machine and the other was the technics of cocoon drying. The problems of the control of the temperature and humidity of the cocoon drying machine and the irrationality of the actual technics of cocoon drying were pointed out with the aim to provide references for the improvement of the machine and the technics.
cocoon drying the air-heated continuous cocoon drying machine temperature and humidity
WANG Liu-xing LING Feng CHEN Qing-guan
College of Material Engineering, Soochow University, Suzhou, Jiangsu 215021, China
国际会议
苏州
英文
111-113
2007-09-13(万方平台首次上网日期,不代表论文的发表时间)