会议专题

Tensile and Tearing Properties of Bi-axial Warp Knitted Flexible Composites

Based on uni-axial tensile testing, The performances of bi-axial warp knitted PET/PVC flexible composites has been analysed in seven in-plane directions, including 0°,15°,30°,45°,60°,75° and 90°. The crack propagation of sample has been observed and analysed by the evaluation of the influence of the crack length and direction under uni-axial tests. The results show that bi-axial warp knitted coated fabric present a strong orthotropic behavior. The tearing strength depends on the initial crack orientation and length. Whatever the crack length and orientation are, the propagation is always perpendicular to the tensile loading direction.

Coated Fabrics Flexible composite Bi-axial Warp Knitted Fabrics Tensile

LUO Yixi HU Hong FANGUEIRO Raul

Department of Textile Engineering and Dress Designing, Shaoxing University, Zhejiang 312000, P. R. C College of Textiles, Donghua University, Shanghai 201620, P. R. China Department of Textile Engineering, University of Minho, Portugal

国际会议

2007年先进纤维与聚合物国际会议

上海

英文

371-373

2007-10-15(万方平台首次上网日期,不代表论文的发表时间)