会议专题

Study on Emission Factor of Internal Comnbustion Locomotive

The measurements of the concentrations of the pollutants from the internal combustion locomotive inside the 3304m long Lishugou rail tunnel in Beijing were conducted. The emission factor of CO and NOx from DF8B locomotive in china were (10.35±8.75)g/(kW·h), (19.50±7.60)g/(kW·h) (passenger locomotive); (27.08±20.78)g/(kW· h), (104.04±48.90)g/(kW·h) (freight locomotive), respectively, which were derived from the conservation of mass on the measured data. In comparison with the emission factors published by developed countries, the CO and NOx emission factors of freight locomotives in China are much higher than those of the advanced countries.

atmospheric environmental science emission factor internal combustion locomotive rail tunnel

GAO Ming REN Fumin ZHANG Yulei YU Min NIU Muchen

School of Civil Engineering & Architecture, Beijing Jiaotong University, Beijing 100044, China

国际会议

2007年中国科协科技年会(The Annual Conference of the China Association for Science and Technology)

武汉

英文

168-171