会议专题

Energetic Comparison between Induction Motors and Synchronous Reluctance Motors

Induction motors are widely used in both industrial and civil applications, but, if speed regulation is needed, some interesting alternatives are today available. An alternative to induction motors is the transverse laminated synchronous reluctance (TLSyR) motor, that shows higher torque capability (in the same stator frame) and higher efficiency. In this paper, two general purpose industrial induction motors (2.2 and 4kW, 4 poles, 380V, 50Hz) are compared with two TLSyR motors, built using the same stator frame of the induction motors. The TLSyR motors are experimentally compared with the induction motors, showing an increment of the efficiency and an increment of the rated torque.

A. Boglietti M. Pastorelli

Politecnico di Torino-Dipartimento di Ingegneria Elettrica (Italy)

国际会议

第五届全球电机系统能效论坛

北京

英文

475-482

2007-06-10(万方平台首次上网日期,不代表论文的发表时间)