会议专题

STUDY ON THE STATIC BEHAVIOR OF VIERENDEEL TRUSS JOINTS REINFORCED WITH INTERNAL STIFFENERS UNDER IN-PLANE BENDING

This paper reports the results of static tests on two vierendeel truss joints reinforced with internal stiffeners in the chord under in-plane bending. The moment-rotation curves and the ultimate capacities were obtained. Test results indicate that the failure modes are composed of weld split, shear deformation and local buckling at the compressive flange of the brace. Such kind of local buckling could be avoided and the stress distribution at the flanges of the brace could also be homogenized by setting a longitude stiffener. However, its deformability is debased due to this way. The calculation comparison indicates that such kind of joints has a higher load bearing capacity than those without internal stiffeners.

Vierendeel tubular truss joint Internal stiffeners Flexural behavior

Shu Yan Wei Wang Yiyi Chen Guofeng Cao Sichun Gu Zhe Zhang

College of Civil Engineering, Tongji University, Shanghai 200092, China Shanghai Institute of Architectural Design & Research Co. Ltd, Shanghai 200041, China

国际会议

The Second International Conference on Advances in Experimental Structural Engineering(第二届实验结构工程进展国际会议)

上海

英文

117-122

2007-12-04(万方平台首次上网日期,不代表论文的发表时间)