会议专题

RESEARCH ON SHAKING TABLE TESTS OF THREE-DIMENSIONAL ISOLATION SYSTEM WITH DISK SPRING

In this paper, a new three-dimensional (3D) isolation system for the building is proposed. The system is composed of lead rubber bearings and disk spring isolators, which is called 3D isolation system. In order to verify the 3D performance of this system, 3D shaking table tests were conducted. The test specimen is 1/2-scale three-story steel structure. The experimental results show that the 3D isolation system can isolate both the horizontal earthquakes and vertical earthquakes.

3D isolation system Disk spring Shaking table test

Yamin Zhao Demin Zeng Jun He Ziping Zhang

College of Architecture and Civil Engineering, Beijing University of Technology, China College of Me Institute of Earthquake Engineering, China Academy of Building Research, China

国际会议

The Second International Conference on Advances in Experimental Structural Engineering(第二届实验结构工程进展国际会议)

上海

英文

351-355

2007-12-04(万方平台首次上网日期,不代表论文的发表时间)