Controlling technology of runout table cooling path for hot strip mill
Target of controlling cooling after rolling has been developing from coiling temperature to cooling rate 、to cooling path 、to microstructure and mechanical property. Under this trend, the object of this article is to discuss the flexible controlling on runout table cooling and to create the relationship between CCT curve and spray bank layout, to make the relationship between cooling rate and spray jet open sequence.This controlling technology has been used successfully in industry experiment ,decreasing the ratio of yield stress and tensile stress in HP 295 steel grade.
laminar cooling spray jet layout stepwise cooling middle temperature cooling rate
佘广夫 彭良贵 刘相华 朱伏先
东北大学轧制技术及连轧自动化国家重点实验室,辽宁 沈阳 110004;攀枝花钢铁集团公司热轧班厂,四川 攀枝花 617062 东北大学轧制技术及连轧自动化国家重点实验室,辽宁 沈阳 110004
国际会议
辽宁
英文
2006-10-21(万方平台首次上网日期,不代表论文的发表时间)