EVALUATION ON THERMAL PERFORMANCE COMBINED WITH MEASUREMENT AND SIMULATION FOR DEVELOPMENT OF ON-SITE EVALUATION METHOD
The last object of this study is to develop standardmethod for building insulation performance on-siteevaluation using Infra-red camera. The goals of thisstudy are 1) to propose the Temperature DifferenceRatio (TDR) which is an on-site evaluation index forbuilding thermal performance, 2) to measure thermalcondition of the mock-up structure as actual buildingstructure by T-type thermocouple sensor and infra-redcamera, 3) to perform heat transfer simulation on the mock-up structure by PHYSIBEL simulationprogram, 4) to analyze measurement and simulationresults.The insulation performance evaluation methodobtained on the basis of the study will be utilized forevaluation of insulation defects after the completionof the construction of a new building and quantitativeevaluation of insulation performance before and afterrepairs, therein contributing to the improvement of the environment and thermal performance of thebuilding.
Thermal performance On-site evaluation method Infra-red thermograph Temperature Difference Ratio (TDR) Heat transfer simulation
Gyoung Soek Choi Kyoung Woo Kim Jae Sik Kang Seung Eon Lee
Building & Urban Research Department, Korea Institute of Construction Technology, Gyeonggi-Do, 411-712, Republic of Korea