HCR OF HEAT PUMP ROOM AIR CONDITIONER IN CHINA
Definition of heating/cooling capacity ratio (HCR) of the heat pump air conditioner has been put forward in this study, and the relationship between supply HCR (HCRS) and demand HCR (HCRD) has been illustrated. Based on the simulated hourly loads of a typical residential building in Haerbin, Beijing, Shanghai and Shenzhen faced to different directions and with different air conditioner running schedules along with the performance of the heat pump air conditioner under varied conditions, the demand heating capacity, cooling capacity and HCRD in different climate subareas have been ascertained. Secondly, a simulation model was built to study the effect of different physical parameters, include the parameters of the indoor heat exchanger, outdoor heat exchanger and compressor, on HCRs of the conventional fixed speed heat pump system to research the possibility to match the HCRD and HCRs in China.
Heating/cooling capacity ratio, Simulation Heat pump, Room air conditioner, Cooling/Heating load
Baolong Wang Wenxing Shi Quan Chen
Department of Building Science, Tsinghua University, Beijing 100084, China
国际会议
北京
英文
2007-09-03(万方平台首次上网日期,不代表论文的发表时间)