RESEARCH ON PERFORMANCE AND OPERATING CHARACTERISTICS OF MULTI-CONNECTED AIR-CONDITIONING SYSTEM

The multi-connected air-conditioning systems are widely used not only in houses but also in large buildings in recent years in China due to their special advantages. But the flexibility also makes the real performances of the systems vary with different applications. A frequency inverter multi-connected air conditioner was designed and assembled. Some key technologies used in such systems were discussed in this paper. The performance and the operating characteristics were also tested and analyzed. Finally, the integrated energy efficiency was calculated and the results shown that the system has a good efficiency in part load.

Multi-connected Air-conditioning Performance operating characteristic part load

Zhang Chaofu Li Hongqi Zhou Binbin Zhao Zhigang

College of Environmental and Energy Engineering, Beijing University of Technology 100, Pingleyuan, Chaoyang District, Beijing P.R.China Beijing, 10022,

国际会议

第五届暖通空调国际研讨会(Proceedings of the 5th International Symposium on Heating,Ventilating and Air Conditioning)

北京

英文

2007-09-07(万方平台首次上网日期,不代表论文的发表时间)