COMFOT REASEARCH OF ENERGY-STORING FLOOR LABORATORY
There are lots of scholars who have researched and analyzed the indoor thermal environment and the thermal comfort in the some regions of China. But the most of the research for the human thermal comfort was carried out in the air-conditioning or common floor heat-storage room, with no research in the phase-change heat-storage electric floor heating system. So, in the laboratory of the Shenyang Jianzhu University, about 200 college-age subjects took part in this survey, which was adopted to analyze statistically the thermal sensation, humidity and draft sensation of the subjects in the energy-storing floor laboratory in different experimental conditions. Conclusion: the neutral temperature is 22.4, the Expectation Temperature is smaller than the neutral temperature, but the difference is very slight; the sensitive degree of women is higher than that of men; the range of temperature of 80% comfort zone is 19.5 25.5, and the range of temperature of 90% comfort zone is 20.8℃~ 24.2℃
SET* thermal comfort energy-storing floor room neutral temperature comfort zone