Analysis of Pulse Performance Based on Cd(Zn)Te Detector Spectrometry

The analysis for pulse waveform is a sticking point for digital pulse processing. In this paper, the waveform of current pulse in Cd(Zn)Te detector and output pulse of preamplifier are analyzed in detail. The cause of formation of pile-up pulse is illuminated. And an identification method for pulse pile-up type by means of digital signal processing technique is offered,which indicates that it is possible to make use of pulses of slight leading-edge pile-up and general lagging-edge pile-up except some severe leading-edge pile-up for digital spectrometry.

digital pulse pile-up mode time-amplitude distribution

Di Yuming Fang Guoming Han Feng Yang Xianming

Xian Research Inst.Of Hi-Tech,Hongqing Town,Xian,P.R.China 710025

国际会议

第八届国际电子测量与仪器学术会议(Proceedings of 2007 8th International Conference on Electronic Measurement & Instruments)

西安

英文