会议专题

Measurement Permanent Volumetric Expansion Ratio for Gas Cylinder

The permanent volumetric expansion ratio is one of the most important parameters in quality estimating of the gas cylinders, and the correctness and accuracy are dependent on the measuring device, which can be improved by the device technical level and weakening the environment influence. In this paper, it discusses the principle and composition of computer-controlled system. The experimental results show that the permanent volumetric expansion ratio tests of the gas cylinder by computer-controlled are more efficient and higher precision than the traditional manual control test and easy to operate; the pressure measurement error is at the range 0.1MPa, volumetric expansion measurement error is at the range 0.1ml.

Gas cylinder permanent volumetric expansion ratio computer control

Lv Qiujuan Zhao Jiuling Hou Genliang

The Second Artillery Engineering Institute,Xian 710025 China;Xi ′an Jiaotong University,Xian 71004 The Second Artillery Engineering Institute,Xian 710025 China

国际会议

第八届国际电子测量与仪器学术会议(Proceedings of 2007 8th International Conference on Electronic Measurement & Instruments)

西安

英文

2007-08-16(万方平台首次上网日期,不代表论文的发表时间)